KEMPER Hygiene System
|KHS CoolFlow
KHS CoolFlow cold water cooler incl. data logger, 100 l
Item number 6100100200 Dimensions including packaging 750 x 650 x 1000 mm; 70 kg
€12,460.33 / Pcs
Tender text
KEMPER KHS CoolFlow cold water cooler
incl. data logger, figure 610 01 002, as
flow-through drinking water cooler for
cooling drinking water with integrated
circulation pump, for cooling the
circulation volume flow and distributing
the cold water as far as the tapping
point outlet in the drinking water
installation, adjustment range of PWC
temperature 15 GradC to 25 GradC,
consisting of PWM-controlled circulation
pump with stainless steel housing and
integrated check valve, consisting of
PWM-controlled operating fluid pump,
with diffusion-tight insulation fitted
at the factory, space requirements less
than 1 MTK, wetted metal parts made from
dezincification-free and
corrosion-resistant gunmetal, resistant
to aggressive water, stainless steel and
drinking water-approved plastics,
low-noise operation, installation on the
ground, incl. drinking water-side
maintenance cut-offs, built-in operating
fluid buffer tank, allows efficient
operation of the cold water generator,
connection to cold water generator
hydraulically separated, integration of
all cold water generators possible,
compact design, plate heat exchanger
made of stainless steel grade
1.4401/1.4404, electronic control unit
for high control quality during
operation, incl. Pt1000 measuring
element, factory pre-assembled
electrical connection of actuators and
sensors to the control unit, Contact for
recharging request, Fault signalling
contact, Data logger and gateway for
connection to the building management
system, Saves all analysable parameters
and serves as interface for the BMS/BA
via Modbus TCP/IP, Data storage on micro
SD card, supplied, Readable and
writeable data points provided via
Ethernet using Modbus TCP/IP log,
Lifetime storage capacity through large
4GB SD card, LAN RJ45 10/100 MBit/s
Ethernet, according to UBA KTW BWGL,
according to UBA BWGL Metals,
ÜA-Reg.-Nr. R-15.2.3-21-17048,
WIEN-ZERT, pressure stage PN 10 drinking
water side and PN 6 equipment side, min.
ambient temperature 0 GradC, max.
ambient temperature 50 GradC, max.
cooling capacity 6.4 kW, power supply
230 V AC, electrical power input 185.5
W, note: maintenance and commissioning
of the plant on request, replaces
version 610 01 000
max. head of cold water circulation pump: 10 m max. flow rate of cold water circulation pump: 2 cbm/h
max. head of cold water circulation pump: 10 m max. flow rate of cold water circulation pump: 2 cbm/h
Documents
Technical documents
File type
Other
File type
Accessories(4)
Spare parts

8 Spare parts
| Pos | Image | Designation |
|---|---|---|
| 1 | ||
| 2 | ||
| 3 | ||
| 4 | ||
| 5 | ||
| 6 | ||
| 7 | ||
| 8 |
6120100100
cooling pump for KHS CoolFlow cold water cooler
6120300100
controller for KHS CoolFlow cold water cooler
6120400100
plate heat exchanger for KHS cold water cooler
6120700100
Skymantle wrapping for KHS CoolFlow cold water cooler
6120800100
top cover for KHS CoolFlow cold water cooler
6120200200
Cold water circulation pump for KHS CoolFlow cold water cooler
6120200100
Cold water circulation pump for KHS CoolFlow cold water cooler
6110000000
Data logger and gateway for KHS Cold Water Cooler