Drinking water fittings

Search Wish list
Filter

Seite 12 / 44 – 1092 Article
kemper Logo
CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 10

CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 10

Typ: CONTROL-PLUS measuring valves
Item no.: 1384G01000
kemper Logo
CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 15

CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 15

Typ: CONTROL-PLUS measuring valves
Item no.: 1384G01500
kemper Logo
CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 20

CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 20

Typ: CONTROL-PLUS measuring valves
Item no.: 1384G02000
kemper Logo
CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 25

CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 25

Typ: CONTROL-PLUS measuring valves
Item no.: 1384G02500
kemper Logo
CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 32

CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 32

Typ: CONTROL-PLUS measuring valves
Item no.: 1384G03200
kemper Logo
CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 40

CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 40

Typ: CONTROL-PLUS measuring valves
Item no.: 1384G04000
kemper Logo
CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 50

CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 50

Typ: CONTROL-PLUS measuring valves
Item no.: 1384G05000
kemper Logo
CONTROL-PLUS flow and temperature sensor, 4
- 20 mA signal, union thread, DN 10

CONTROL-PLUS flow and temperature sensor, 4 - 20 mA signal, union thread, DN 10

Typ: CONTROL-PLUS measuring valves
Item no.: 1386G01000
kemper Logo
CONTROL-PLUS flow and temperature sensor, 4
- 20 mA signal, union thread, DN 15

CONTROL-PLUS flow and temperature sensor, 4 - 20 mA signal, union thread, DN 15

Typ: CONTROL-PLUS measuring valves
Item no.: 1386G01500
kemper Logo
CONTROL-PLUS flow and temperature sensor, 4
- 20 mA signal, union thread, DN 20

CONTROL-PLUS flow and temperature sensor, 4 - 20 mA signal, union thread, DN 20

Typ: CONTROL-PLUS measuring valves
Item no.: 1386G02000
kemper Logo
CONTROL-PLUS flow and temperature sensor, 4
- 20 mA signal, union thread, DN 25

CONTROL-PLUS flow and temperature sensor, 4 - 20 mA signal, union thread, DN 25

Typ: CONTROL-PLUS measuring valves
Item no.: 1386G02500
kemper Logo
CONTROL-PLUS flow and temperature sensor, 4
- 20 mA signal, union thread, DN 32

CONTROL-PLUS flow and temperature sensor, 4 - 20 mA signal, union thread, DN 32

Typ: CONTROL-PLUS measuring valves
Item no.: 1386G03200
kemper Logo
CONTROL-PLUS flow and temperature sensor, 4
- 20 mA signal, union thread, DN 40

CONTROL-PLUS flow and temperature sensor, 4 - 20 mA signal, union thread, DN 40

Typ: CONTROL-PLUS measuring valves
Item no.: 1386G04000
kemper Logo
CONTROL-PLUS flow and temperature sensor, 4
- 20 mA signal, union thread, DN 50

CONTROL-PLUS flow and temperature sensor, 4 - 20 mA signal, union thread, DN 50

Typ: CONTROL-PLUS measuring valves
Item no.: 1386G05000
kemper Logo
Multi-T adapter, union thread, DN 15

Multi-T adapter, union thread, DN 15

Typ: MULTI-T adapter
Item no.: 1280G01500
kemper Logo
Multi-T adapter, union thread, DN 20

Multi-T adapter, union thread, DN 20

Typ: MULTI-T adapter
Item no.: 1280G02000
kemper Logo
Multi-T adapter, union thread, DN 25

Multi-T adapter, union thread, DN 25

Typ: MULTI-T adapter
Item no.: 1280G02500
kemper Logo
Multi-T adapter, union thread, DN 32

Multi-T adapter, union thread, DN 32

Typ: MULTI-T adapter
Item no.: 1280G03200
kemper Logo
Multi-T adapter, union thread, DN 40

Multi-T adapter, union thread, DN 40

Typ: MULTI-T adapter
Item no.: 1280G04000
kemper Logo
Multi-T adapter, union thread, DN 50

Multi-T adapter, union thread, DN 50

Typ: MULTI-T adapter
Item no.: 1280G05000
kemper Logo
gunmetal sampling valve, DN 8, for DN 15-50

gunmetal sampling valve, DN 8, for DN 15-50

Typ: Sampling valves
Item no.: 1870000600
kemper Logo
gunmetal sampling valve, DN 10, for DN 65-150

gunmetal sampling valve, DN 10, for DN 65-150

Typ: Sampling valves
Item no.: 1870001000
kemper Logo
SST sampling valve, DN 8, for DN 15-50

SST sampling valve, DN 8, for DN 15-50

Typ: Sampling valves
Item no.: 0870000600
kemper Logo
SST sampling valve, DN 10, for DN 65-150

SST sampling valve, DN 10, for DN 65-150

Typ: Sampling valves
Item no.: 0870001000
kemper Logo
Neu
Built-in valve, female pipe thread, DN 15

Built-in valve, female pipe thread, DN 15

Typ: Flush mounted valves
Item no.: 5650101500

  • 10
  • 11
  • 12
  • 13
  • 14
kemper Logo

CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 10

CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, DN 10 -
Item number 1384G01000
Prices (WLP) €666.68
Main product group Measuring valves
Product group CONTROL-PLUS measuring valves
Dimensions including packaging 123 x 139 x 63 mm; 0.3 kg
Ausschreibungstext
KEMPER CONTROL-PLUS flow and temperature sensor, Hz signal, union thread, figure 138 4G, frequency output signal, for the accurate measurement of flow rates and temperatures in drinking water systems, wetted metal parts made from dezincification-free and corrosion-resistant gunmetal, resistant against aggressive water, sensor housing for low pressure loss, up to 50% of measuring range: divergence max. 1% of full-scale reading, from 50% of measuring range: deviation max. 2% of measured value, for connection to the KHS control systems, male union thread, free from dead spots, with vortex flow sensor that includes a 2-wire Pt1000, 5-pin M12x1 interface, readout and display of values via additional available KHS potable measuring instrument, WRAS approval, according to UBA KTW BWGL, according to UBA BWGL Metals, ÜA-Reg.-Nr. R-15.2.3-21-17048, WIEN-ZERT, pressure rating PN 10, min. flow velocity 0.2 m/s, max. flow velocity 2.5 m/s, min. operating temperature 0 GradC, max. operating temperature 100 GradC, protection class IP65, power supply 5 V DC, note: optional cable M12x1 required for connection to KHS control systems, DN 10 is recommended for use with flow limiter 2 l/min
Features
Type of fitting: Measuring device
Housing style: Durchgang
Housing material: Rotguss
Kvs value: 1.90 m³/h
Nominal width: 10 DN
Max. operating temperature: 100 °C
Connections
Inlet G 3/4
Outlet G 3/4
Performance curve is loading...
REACH statement (PDF) Building technology valves and systems (PDF) Installation and operating instructions CONTROL-PLUS flow and temperature measuring fitting (PDF) Link to the website (HTML)
Revit-Families COBie-Standard (RFA)
Click to load Accessories
QR Code
imprint Data protection Terms and Conditions