GS LipuLift-PF-B NS7-flex&SAT100
Item number 3207.30.01 Dimensions including packaging 3260 x 1160 x 1670 mm; 351.99 kg
€10,025.51 / Pcs
Tender text
ACO LipuLift-PF-B NS 7 – Hgeo max: 6
Meter
- Flexibel
Grease separator NS 7 manufactured
according to EN 1825-1 of PE-HD for
below ground installation with an
integrated duo pumping station
according to EN 12050-2, trade
separation on request
Container buoyancy-proof from the
container bottom up to a height of 1
,650 mm (all load classes) with on-site
concrete slab (class A15/class B125)
respectively with a concrete load
distribution slab
(load class D)
Two access openings, each to accommodate
a top section with covers
according to either class A, B or D
- minimum and maximum inlet depth
depends on chosen top section and type
of load class
Cleaning and emptying the separator by
opening the shaft covers
Integrated sampling option via the
access cover in the pumping station
segment
Integrated pumping station in accordance
with EN 12050-2 accessible via
an access cover
- Pressure connection: diam. 63 mm (PE
pipe)
- Ball backflow preventer
- Hgeo max. (recommendation) = 6 m
- Power: P1 = 1.15 kW, P2 = 0.88 kW
- Voltage: 400 V, 50 Hz,
- Speed: 2900 rpm
- Protection class IP 68
- Operating mode: S1
- Open multi-channel impeller
Level measurement either via ACO
pressure transducer (4-20 mA) or
dynamic pressure bell with air bubble
injection (see accessories).
ACO Multi Control Duo switching device
for pump control
- LCD plain text display
- internal acoustic alarm
- Flood alarm potential-free
- ATEX mode
- electronic monitoring of the motor
current
- Collective fault message
potential-free and potential bound
- Connection to Building Monitoring
Systems via digital and analogue
input and outputs
- Rotary field and phase failure control
(to be activated via the menu)
- Runtime monitoring
- Analogue outputs 0-10 V and 4-20 mA
- Fault memory
- Housing size WxHxD: 320 x 300 x 120 mm
- Operating voltage: 400 V
- Frequency: 50/60 Hz
- Control voltage: 230 V / AC / 50 / Hz
- Power consumption in idle mode: max.
10 VA
- Temperature range: -20 to + 60 ° C
- Protection class IP 54
- Pre-assembled three-phase current
cable 5x4 mm2 and CEE 32 plug with
phase inverter
- Cable entry
Inlet and outlet: OD Ø 160 mm
Ventilation connection: OD Ø 110 mm for
joint venting of the separator
and pumping station
Length x width x height: 3,260 mm x
1,160 mm x 1,670 mm
Installation depth maximum: 3,000 mm
Total volume: 1,760 liters
Fat storage volume: 550 liters
Sludge trap volume: 780 liters
Empty weight: approx. 240kg
DoP: BD/G1/1012
Technical data
Features
Nominal size 7.0
Sludge trap content 780 l
Fat storage content 550 l
Total content 1760 l
Installation site Erdeinbau
Material PE
Connections
Inlet STECK-MUFF-DN 150
Outlet STECK-MUFF-DN 150
Undefined STECK-NIPP-DN 100
Connection STECK-NIPP-DN 150
Connection STECK-NIPP-DN 150