LP Muli-Mini MDP1.1 400V/50Hz
Item number 1206.00.05 Dimensions including packaging 1200 x 800 x 1000 mm; 42 kg
€2,853.74 / Pcs
Tender text
ACO Waste water lifting plant Muli-Mini
MDP 1.1
for grey water with faeces
test according to DIN EN 12050-2
Compact design for above ground
installation
consits of:
Collection tank made of polyethylene
with drain plug R",
with connection for diaphragm manual
pump DN 50
with fixation kit for operationally
secure attachment
Revision opening for simple maintenance,
ø 340 mm
Tank dimensions: (LxWxH): 815 x 600 x
850 mm
Adapted for a minimum installation
opening of 700mm
ergonomic carry handles allivate the
transport
e.g steep cellar stairs
Tank design allows space saving corner
installation.
Total Volume: 205 Litres
Usable Volume:
Inlet height 250mm: 60 Litres
Inlet height 400mm: 108 Litres
Vertical Inlet: 140 Litres
Connection Inlet:
2x horizontal Inlets DN 100, Inlet
height 250mm
2x Horizontal Inlets DN 100, Inlet
height 400mm
1x Vertical Inlet DN 100
alternatively:vertical Inlet DN 50
(accessories)
Connection pressure line:
1 ball retaining valve 2" with stainless
steel pipes,
material grade 316
1 ball retaining valve 2" with special
mounting adapter
DN50 for elastic connection 57-61mm pipe
external
diameter pressure line
With ventilation
sockets DN 70
suitable for plastic or SML pipe
mounted in tank:
1 submersible waste water pump
Sat-VX 75 D
Three-phase submersible motor,
protection class IP 68,
power: P1= 0,75 kW, P2= 0,55 kW
Voltage: 400 V, frequency 50 Hz
current consumption 1,3 A, 2900 rpm.
with mechanical seal,
with non-clogging free-flow
impeller,
grain size 40 mm.
With Simmerring/glide ring sealing
secondary oil storage tank
with blockage
- free free flow impeller
made of plastic
With pneumatic level control
- Protection class IP 54
- ready to plug in, with 1,5 m cable and
CEE16- plug
- potential free collective fault and
operation signal
- mains-independent alarm and battery
(85dBA, 5-6h)
- numerical display with status
indication
- digital potentiometer for setting pump
1
ON and OFF, high water alarm, motor
current limitation
- level measurement and sensor
monitoring
- rotating field control
- H-0-A push button
- Display of service intervals
- Operating hours counter and display of
switch-on pulses
- ammeter
- simple error memory (last errors)
- control preset and multilingual
- With 230V connection for power supply
air bubbling
- Housing size WxHxD: 160x160x145 mm
(measured with cable gland)
weight: approx.50 kg
Optional as accessories:
hexagon bold 2" x 2" made of stainless
steel
Special fastening piece
Air bubble injection.....